Search results for "imaging [Stars]"
showing 10 items of 415 documents
Analysis of thermal infrared data from the Digital Airborne Imaging Spectrometer
2001
Thermal infrared data of the Digital Airborne Imaging Spectrometer (DAIS), whose channels 74-79 are in the 8-13 w m waveband region, were analysed with the aim of recovering land surface temperature (LST). DAIS images were acquired over an experimental site where field and laboratory emissivity measurements were performed, and these were used to recover the LST from the six DAIS thermal channels. Atmospheric correction of DAIS data was calculated by means of a nearby radiosounding and a radiative transfer model. DAIS derived LSTs were compared with ground measurements of LST made coincidentally for a few test fields, the central DAIS channels yielding temperatures up to 10°C higher than gro…
Spatial homogeneity from temporal stability: Exploiting the combined hyper-frequent revisit of Terra and Aqua to guide Earth System Science
2021
Abstract The terrestrial component of the Earth system has witnessed considerable changes in the past decades due to anthropogenic action. Throughout this period, the NASA Terra mission has been constantly monitoring the surface with the Moderate Resolution Imaging Spectroradiometer (MODIS) instrument. When combined with the MODIS instrument on-board of the Aqua platform, we obtain a hyper-frequent revisit capability providing sub-daily observations globally at a moderate resolution of ~250 m, but with a strong multi-angular variation of the observation footprint. Here we propose to exploit this particular configuration provided by the combined Terra + Aqua constellation to infer spatial ho…
Noninvasive cardiovascular imaging for evaluating subclinical target organ damage in hypertensive patients: a consensus article from the European Ass…
2017
International audience; : Arterial hypertension accounts for the largest amount of attributable cardiovascular mortality worldwide, and risk stratification in hypertensive patients is of crucial importance to manage treatment and prevent adverse events. Asymptomatic involvement of different organs in patients affected by hypertension represents an independent determinant of cardiovascular risk, and the identification of target organ damage is recommended to further reclassify patients' risk. Noninvasive cardiovascular imaging is progressively being used and continues to provide new technological opportunities to target organ damage evaluation at early stage. The aim of this article is to pr…
Evaluation of Hybrid Models to Estimate Chlorophyll and Nitrogen Content of Maize Crops in the Framework of the Future CHIME Mission
2022
In the next few years, the new Copernicus Hyperspectral Imaging Mission (CHIME) is foreseen to be launched by the European Space Agency (ESA). This mission will provide an unprecedented amount of hyperspectral data, enabling new research possibilities within several fields of natural resources, including the “agriculture and food security” domain. In order to efficiently exploit this upcoming hyperspectral data stream, new processing methods and techniques need to be studied and implemented. In this work, the hybrid approach (HYB) and its variant, featuring sampling dimensionality reduction through active learning heuristics (HAL), were applied to CHIME-like data to evaluate the…
Mapping a-priori defined plant associations using remotely sensed vegetation characteristics
2014
Abstract Incorporation of a priori defined plant associations into remote sensing products is a major challenge that has only recently been confronted by the remote sensing community. We present an approach to map the spatial distribution of such associations by using plant indicator values (IVs) for salinity, moisture and nutrients as an intermediate between spectral reflectance and association occurrences. For a 12 km 2 study site in the Netherlands, the relations between observed IVs at local vegetation plots and visible and near-infrared (VNIR) and short-wave infrared (SWIR) airborne reflectance data were modelled using Gaussian Process Regression (GPR) (R 2 0.73, 0.64 and 0.76 for sali…
SIRM–SIC appropriateness criteria for the use of Cardiac Computed Tomography. Part 1: Congenital heart diseases, primary prevention, risk assessment …
2021
AbstractIn the past 20 years, Cardiac Computed Tomography (CCT) has become a pivotal technique for the noninvasive diagnostic work-up of coronary and cardiac diseases. Continuous technical and methodological improvements, combined with fast growing scientific evidence, have progressively expanded the clinical role of CCT. Recent large multicenter randomized clinical trials documented the high prognostic value of CCT and its capability to increase the cost-effectiveness of the management of patients with suspected CAD. In the meantime, CCT, initially perceived as a simple non-invasive technique for studying coronary anatomy, has transformed into a multiparametric “one-stop-shop” approach abl…
Modulation transfer function in refractive-diffractive multifocal intraocular lenses in vitro
2007
Purpose: The optical quality of two types of multifocal, hybrid refractive-diffractive, intraocular lenses (IOL) is analyzed in vitro. Following the EN-ISO international standard, the IOLs’ modulation transfer functions (MTF) are determined for both distance and near vision. The behaviour of these curves when the pupil size varies is studied. Methods: The IOLs analyzed were: AcrySoft ResTor SN60D3 (Alcon) and Tecnis ZM900 (AMO). The MTF was calculated from the cross line-spread function recorded with the OPAL Vector System (Image Science Ltd. Oxford) by using fast Fourier transform techniques. The artificial eye model used simulates in vivo conditions of the anterior chamber including an ar…
Frequency Based Detection and Monitoring of Small Scale Explosive Activity by Comparing Satellite and Ground Based Infrared Observations at Stromboli…
2014
Abstract Thermal activity is a common precursor to explosive volcanic activity. The ability to use these thermal precursors to monitor the volcano and obtain early warning about upcoming activity is beneficial for both human safety and infrastructure security. By using a very reliably active volcano, Stromboli Volcano in Italy, a method has been developed and tested to look at changes in the frequency of small scale explosive activity and how this activity changes prior to larger, ash producing explosive events. Thermal camera footage was used to designate parameters for typical explosions at Stromboli (size of spatter field, cooling rate, frequency of explosions) and this information was a…
Radiative heat power at Stromboli volcano during 2000–2011: Twelve years of MODIS observations
2012
Abstract Twelve years of night-time MODIS (Moderate Resolution Imaging Spectroradiometer) observations, has been analysed to detect and quantify the radiative heat power emitted by Stromboli volcano (from March 2000 to September 2011). Using an accurate background subtraction of the MODIS signal at 4 μm, we were able to discriminate two main regimes of thermal radiation, related to different levels of volcanic activity. Effusive eruptions (occurred on December 28, 2002 and February 27, 2007) radiated at an average of ~ 186 MW with a frequency of alert detection of 50–95%. Conversely, during the typical strombolian activity, an average of ~ 9 MW is radiated, with a frequency of alert detecti…